Determine mass flow rate of refrigerant
WebA Refrigerator is designed to operate using refrigerant R-513a and is required to remove 78 kW of energy from the evaporator if the operating condtions of the plant are as follows caiculate the required mass flow rate of the refrigerant assuming no losses: Give your arfswer in kg/hr Operating Conditions:- Compressor - Inlet condition 1 bar dry ... WebThe rate of refrigeration of the cycle is to be 10.55 kW of refrigeration. Determine the coefficient of performance of the device as a refrigerator and the mass flow rate of R-134a needed for (a) an isentropic compressor and (b) an isentropic compressor efficiency of 0.75.
Determine mass flow rate of refrigerant
Did you know?
Webi.e., the flow of mass m through a surface per unit time t.. The overdot on the m is Newton's notation for a time derivative.Since mass is a scalar quantity, the mass flow rate (the time derivative of mass) is also a scalar quantity. The change in mass is the amount that flows after crossing the boundary for some time duration, not the initial amount of mass at the … http://rpaulsingh.com/lectures/refrigeration.pdf
Webd) the mass flow rate of refrigerant in long tons per hour, e) the work input needed in the system in kW, f) the heat rejected in the condenser in kCal/min g) the coefficient of performance, h) the volume flow rate at suction in cfm, i) the corresponding saturation temperature at low pressure side in °R, 1) the corresponding saturation ... WebRefrigerant-134a is the working fluid in an ideal compression refrigeration cycle. The refrigerant leaves the evaporator at -20oC and has a condenser pressure of 0.9 MPa. …
Web(a) Calculate the steam mass flow rate (kg/s) through the boiler. (b) Compute the isentropic efficiency (%) of the adiabatic turbine. (c) Find the entropy generation (kW/K) for the adiabatic turbine. (d) Determine the total entropy generation (kW/K) for the condenser assuming heat transfer occurs to an environment of temperature 5 C. WebRefrigerant-134a is to be cooled by water in a condenser. The refrigerant enters thecondenser with a mass flow rate of 6 kg/min at 1 MPa and 80°C and leaves at 30°C. The coolingwater enters at 500 kPa and 20°C and leaves at 40°C. Neglecting any pressure drops, determinethe mass flow rate of the cooling water required.
WebThe refrigerant enters the condenser at 1.2 MPa and 50°C and leaves at the same pressure subcooled by 5°C. If the compressor consumes 3.3 kW of power, determine …
WebWe would like to show you a description here but the site won’t allow us. cinnamon flake cereal smallWebAug 17, 2024 · 1. Touching the inhaler and exhaust pipe to sense the heat and cold of the copper pipe. 2. Observe the bubbles in the retinoscope. 3. Measuring high and low-pressure pressure. 4.Measuring the current of the compressor. 5.Calculate the superheat. 6.Calculate the subcooling degree. diagram of 24 volt from 2 12 volt batteriesWebIt is specified that the temperature rise of the water not exceed $4^{\circ} \mathrm{C}$ The power dissipation of the box is $2 \mathrm{kW}$, which is removed entirely by water. If the box operates 24 hours a day, 365 days a year, determine the mass flow rate of water flowing through the box and the amount of cooling water used per year. cinnamon flakes cereal caloriesWebSep 23, 2024 · Method to Calculate the Refrigerant Mass Flow Rate. 3.1. Validation of Adiabatic Process Hypothesis in the Expansion Phase and Compression Phase. As … diagram of a 2002 gmc yukon xl sound systemWebNov 1, 2011 · where mass flow rate and h is specific enthalpy. From a calculation viewpoint alone, the power calculation is particularly sensitive to the specification of flow rate, inlet temperature and pressure, and outlet pressure. ... Calculate enthalpy h 1 =f(P 1, T 1, and composition) and suction entropy s 1 =f(P 1, T 1, and composition) at the suction ... diagram of 2.4 liter gm engineWebIf the compressor consumes 6.26 kW of power, accordingly determine a) The mass flow rate of the refrigerant, b) The rate of heat supply, c) The COP, and d) The minimum power input to the compressor for the same rate of heat supply. Note: You may use Thermodynamics Tables by Michael J. Moran for this question. diagram of 4 3 liter chevy silverado engineWebSince no mass flow rate of the refrigerant has been provided, the entire analysis is done in terms of specific energy values. Notice that the same system can be used either for a refrigerator or air conditioner, in which the heat absorbed in the evaporator (q evap ) is the desired output, or for a heat pump, in which the heat rejected in the ... cinnamon flavored candies